1.
Radiat Prot Dosimetry ; 188(2): 181-190, 2020 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-31838516

RESUMO

In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools' capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Idoso , Finlândia , Fluoroscopia , Humanos , Doses de Radiação , Radiografia Intervencionista , Pele
2.
Radiat Prot Dosimetry ; 185(4): 483-493, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30989216

RESUMO

The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm2) and PCIs (KAP 75 cm2), and novel levels for PIs (KAP 3.5 Gycm2), atrial fibrillation ablation procedures (KAP 25 Gycm2) and TAVI (KAP 90 Gycm2). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm2), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm2) and atrial flutter procedures (KAP 16 Gycm2). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.


Assuntos
Cardiologia/normas , Doses de Radiação , Radiografia Intervencionista/métodos , Radiologia Intervencionista/normas , Radiometria , Idoso , Valva Aórtica/cirurgia , Nó Atrioventricular/patologia , Cardiologia/métodos , Angiografia Coronária , Eletrofisiologia , Feminino , Finlândia , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Radiologia Intervencionista/métodos , Valores de Referência , Taquicardia/patologia